Hioki LCR HiTester 3535

High-frequency 100kHz to 120MHz LCR Tester for High Speed Testing of Chip Inductors and Magnetic Heads during Research and Development

Hioki LCR and Impedance Analyzers range from 4Hz to 120MHz devices to suit a wide range of applications in the testing of electronic components. The 3535 leads the Hioki lineup in terms of measurement frequency, supporting up to a 120MHz source frequency, and is used with a multi-range, detachable head amp to meet not only production but also R&D applications, paving the way for more efficient testing of resonance frequency components such as those used in non-contact IC cards or tags that incorporate RF-ID technology.

A Head Amp Unit 9700-10 must be factory adjusted for dedicated use with the 3535 before delivery.

This product is not supplied with test fixtures. Please select and purchase the test fixture options appropriate for your application separately.

High speed LCR testing (6ms/sample)
• Load compensation function
• BIN (Classification) Measurement
• Memory capable of storing up to 200 measured values
• Detachable head amplifier
• Print measured values and comparator results with the Printer 9442 (option)

Basic specifications (Accuracy guaranteed for 6 months)

Measurement parameters |Z|, |Y|, θ, Rp, Rs (ESR), G, X, B, Cp, Cs, Lp, Ls, D (tanδ), Q
Measurement range 1 k/10 k/100 kΩ (Depend on the 9700-10, All parameters defined by |Z|)
Extent of measurement impedance (Note: All measurement ranges except for |Z| are for reference only) 1 kΩ range 10 kΩ range 100 kΩ range
  Z, R 100 mΩ to 2 kΩ 1 kΩ to 20 kΩ 10 kΩ to 300 kΩ
  C 0.66 pF to 15.9 μF 0.066 pF to 1.59 nF 4.4 fF to 159 pF
  L 0.133 nH to 3.18 mH 1.33 μH to 31.8 mH 13.3 μH to 477 mH
  θ -180.00° to 180.00°
Basic accuracy |Z|: ±0.5 % rdg., phase angle: ±0.3° (typ.)
Measurement frequency 100 kHz to 120 MHz (100 Hz to 100 kHz steps)
Measurement signal level 5 mV to 1 V, 20 mA max. (100 kHz to 10.00 MHz)
5 mV to 500 mV, 10 mA max. (10.01 MHz to 120 MHz), (1 mV steps)
200 µA to 20 mA: 1 V max. (100 kHz to 10.00 MHz)
200 µA to 10 mA: 0.5 V max. (10.01 MHz to 120 MHz), (10 µA steps)
Output impedance 50 Ω (at 100 kHz)
Display LCD with backlight display, 99999 (3, 4, or 5 digits unit setting possible)
Measurement time 6 ms (nominal)
DC bias N/A
Functions Load compensation function, Classification (BIN) Measurement, Comparator, Averaging, External input/Output (EXT. I/O), GP-IB or RS-232C interface
Power supply 100V to 240 V AC, 50/60 Hz, 50 VA max.
Dimensions and mass 360mm (14.17in) W × 130mm (5.12in) H × 360mm (14.17in) D, 8.3kg (292.8oz)
Accessories Quick start manual × 1, Instruction manual × 1, Power cord × 1

Location