GW Instek

Sub Categories

00
Stemming from the design and manufacture demands of electronic industries, GW Instek offers diverse...
31
In addition to provid complete electronic test and measurement instruments, GW Instek...
5
The GW Instek Basic Test & Measurement instruments can be divided into 4 groups: Digital...
  • Filter
Created on: 30 October 2014

Features: ※ Easy-Operating Tester, Particularly be Designed for the Digital IC ※ Supported Device:74/54/40/45 Serial, Drive 2xxx ※ Small, Portable, Light and Power-Saving, Usable With Battery ※ Average Search Time: 0.6 Second ※ Display: 16 Characters in 1 Line LCD ※ Test Pins: 14~24 Pins

Created on: 30 October 2014

Features: ※ Automatic level & distortion measurements ※ Auto or Hold function selectable ※ 0.1% ~ 100% in 7 distortion measuring ranges ※ 20Hz ~ 20kHz in 3 continuous ranges ※ 400Hz, 1kHz, 10kHz 3 frequency spots ※ 1mVrms ~ 300Vrms in 12 ACV measuring ranges  

Created on: 30 October 2014

Features: ※ 300μV Full Scale Sensitivity ※ Measurement Frequency: 10Hz ~ 1MHz ※ Measurement Amplitude: -70dB ~ +40dB in 12 Ranges ※ Dual Channel (GVT-427B)※ CE Approved (GVT-417B)

Created on: 30 October 2014

Features: ※ Frequency and Period Measurement※ High Resolution at Both High and Low Frequency※ 0.01Hz~2.7GHz Frequency Range(GFC-8270H)※ 0.01Hz~1.3GHz Frequency Range(GFC-8131H)※ 10mV rms High Sensitivity ※ 100nHz Resolution for 1Hz Input ※ Variable Trigger Level Control※ Microprocessor Controlled Intelligent Counter(only GFC-8270H)

Created on: 30 October 2014

Features: ※ 10Hz ~ 120MHz Range ※ 8 Digits Display (0.3"LED) ※ 15mV rms High Sensitivity ※ 5PPM High Stability Time Base ※ Frequency and Period Measurement ※ Low Pass Filter Function ※ Over-Flow Indicatot

Created on: 30 October 2014

Features: ※ Simultaneous Display of W, A, V ( PF or Hz ) ※ True RMS V, A, W ※ Auto Calibration Via Computer ※ Max. / Min. / Hold Function ※ High Immunity to External Noise ※ CT Ratio (1 ~ 9999) ※ PT Ratio (1 ~ 9999)

Created on: 30 October 2014

Features: ※ Combining a Logic Probe and Pulser Combined into One ※ Probe for Troubleshooting Digital Circuits ※ Operating Voltage: 4VDC ~ 18VDC※ Maximum Input Signal Frequency: 50MHz ※ TTL: Logic “1”>3.0V±0.25V, Logic”0”<0.75±0.25V ※ CMOS: Logic “1”>60%VCC±5%, Logic”0”<15%VCC±5% ※ Minimum Detectable Pulse Width: 10nsec ※ Pulser: Sync input impedance 120kΩ ※ Pulse Repetition Rate: Switchable 0.5/400Hz ※ Pulse width: 10μsec ※ Dimensions & Weight: 18(W)x210(H)x18(D)mm, Approx. 50g

Created on: 31 October 2014

Features * Wideband, Upper Resonant Frequency 1GHz* Primary Sensor Type : H-Field* Weight (kg) : 0.25* For : GSP-Series(An addirional ADP-001 & GTL-110 is needed for fitting GSP spectrum analyzers)